BTU Calculator for Air Conditioners
Air conditioner size
8,800 BTU/hr
For 320 sq ft, based on the ENERGY STAR sizing chart
- Common unit size
- 10,000 BTU/hr
- The smallest common size that covers the need
- ENERGY STAR chart base
- 8,000 BTU/hr
- For an 8 ft ceiling and 2 people
- Ceiling and sun
- +800 BTU/hr
- ±10% for shade or sun
- Extra people
- +0 BTU/hr
- 600 BTU/hr for each person above 2
- Kitchen
- +0 BTU/hr
- 4,000 BTU/hr when the room is a kitchen
- In kilowatts
- 2.58 kW
- 0.73 tons
What if the room were different
If the room were heavily shaded
7,200 BTU/hr
−1,600 BTU/hr; buy 8,000 BTU/hr
If the room had average sun
8,000 BTU/hr
−800 BTU/hr; buy 8,000 BTU/hr
If it were a kitchen
12,800 BTU/hr
+4,000 BTU/hr; buy 14,000 BTU/hr
A unit that is too large cools the air before it removes the humidity, so the room feels damp. For a whole house, a contractor's Manual J load calculation is more reliable than any rule of thumb.
ENERGY STAR room air conditioner sizing chart
| Room area | Cooling capacity | Match |
|---|---|---|
| 100 sq ft to 150 sq ft | 5,000 BTU/hr | |
| 150 sq ft to 250 sq ft | 6,000 BTU/hr | |
| 250 sq ft to 300 sq ft | 7,000 BTU/hr | |
| 300 sq ft to 350 sq ft | 8,000 BTU/hr | Your room |
| 350 sq ft to 400 sq ft | 9,000 BTU/hr | |
| 400 sq ft to 450 sq ft | 10,000 BTU/hr |